eCO2 3D 40 W fractional CO2 laser for scars, wrinkles and skin resurfacing

The next generation of eCO2: more power, 3D Controlled Chaos Technology and zero consumables.

Cynosure Lutronic eCO2 3D fractional CO2 laser
Cynosure Lutronic logo

WHY CHOOSE IT

ECO2 3D BENEFITS

1

40 W of power

A third more power than the previous eCO2: deeper, cleaner ablation zones.

2

3D Controlled Chaos

Microbeams placed in a pseudo-random order: less heat build-up, less redness and faster recovery.

3

Zero consumables

No per-treatment consumable costs, for a higher return on investment.

Detail of the eCO2 3D fractional CO2 laser

eCO2 3D is manufactured by Cynosure Lutronic. Bioskin Italia distributes it in Italy and supports every installation with clinical training, technical service and marketing support.

THE PRODUCT

What is eCO2 3D

eCO2 3D is an ablative fractional CO2 laser for skin resurfacing: it creates micro-columns of ablation that remove damaged tissue and trigger collagen remodelling. It is the evolution of the Lutronic eCO2, with up to 40 W of power, 3D Controlled Chaos Technology, three interchangeable tips and Static and Dynamic modes. It covers very different treatments: from a light Precision Peel with minimal downtime to deep resurfacing of acne scars, surgical scars and wrinkles.

Cynosure Lutronic eCO2 3D fractional CO2 laser

THE TECHNOLOGY

How the eCO2 3D fractional CO2 laser works

The beam is narrow and tapered: it drives energy deep and limits lateral heat spread. The micro-columns of ablation are surrounded by healthy skin, which speeds up healing and triggers new collagen production.

3D Controlled Chaos Technology

Microbeams are fired in a pseudo-random order, each as far as possible from the previous one. Heat does not build up, the untreated skin between beams stays protected, and discomfort, redness and recovery time are reduced.

Three interchangeable tips

The 120 µm tip works in the deep dermis with fast healing, the 300 µm tip in the mid-dermis and the 500 µm tip on the epidermis for superficial dyschromia. The system recognises each tip automatically, with no recalibration.

Static mode

Precise stamping over scanned areas up to 18×18 mm, with selectable density. This is the mode for targeted, deep resurfacing: scars, tightening and wrinkle reduction.

Dynamic mode

Energy is delivered in motion to blend treated and untreated areas and avoid a grid pattern. Full-face tone and texture treatments become faster and gentler, with treatment time nearly halved.

INDICATIONS

What eCO2 3D treats

Scars

  • Atrophic acne scars
  • Raised or depressed surgical scars
  • Extensive scarring

Wrinkles and texture

  • Wrinkles, fine lines and folds
  • Irregular skin texture
  • Full-face resurfacing

See also our other devices for wrinkle treatment.

Dyschromia and Precision Peel

  • Pigmented lesions and superficial dyschromia
  • Uneven skin tone
  • Low-downtime Precision Peel

For a non-ablative treatment there is the Mosaic 3D laser.

See all the devices for skin resurfacing and rejuvenation distributed by Bioskin Italia.

TECHNICAL SHEET

Technical data

Laser type Ablative fractional CO2
Power Up to 40 W
Scanning 3D Controlled Chaos Technology
120 µm tip Deep dermis; 1–17% coverage per pass
300 µm tip Mid-dermis; 5–58% coverage per pass
500 µm tip Epidermis; 20–130% coverage per pass
Tip recognition Automatic, no recalibration
Modes Static (scan area up to 18×18 mm) and Dynamic
Pulses Char-free modes to control thermal damage
Consumables None

RESULTS, NOT WORDS

ECO2 3D: BEFORE AND AFTER

Before and after 1 treatment. Photos courtesy of Zena Gabriel, MD and Melanie Palm, MD.

Facial wrinkles before eCO2 3D treatmentFacial wrinkles after 1 eCO2 3D treatment
Pigmentation on the back of the hand before eCO2 3D treatmentBack of the hand after 1 eCO2 3D treatment

eCO2 3D with Bioskin Italia

Bioskin Italia has been distributing aesthetic medicine devices since 1997. With eCO2 3D we provide installation and clinical training at your clinic or through training days at the partner medical centres we work with, after-sales technical service and maintenance contracts, and marketing support to launch the treatment.

eCO2 3D is also available through leasing or operating rental. After treatment, it can be combined with Healite II LED phototherapy to support recovery.

FAQ

eCO2 3D frequently asked questions

What is the difference between eCO2 and eCO2 3D?

eCO2 3D is the evolution of eCO2: it reaches 40 W of power, a third more, and introduces 3D Controlled Chaos Technology and Dynamic mode. The result is deeper, cleaner ablation zones with less heat build-up in the skin.

How long is recovery?

It depends on intensity. After a light Precision Peel there is mild redness for 6–48 hours. After deep resurfacing redness can last a week or more, and most patients return to normal activities in about 5 days.

Is the treatment painful?

Sensitivity varies from patient to patient. The physician usually applies a numbing cream before treatment, and 3D Controlled Chaos Technology limits heat build-up and therefore discomfort.

Are there consumable costs?

No. eCO2 3D uses no consumables: the tips are interchangeable and carry no per-treatment cost.

Can I see eCO2 3D in action before buying?

Yes: we can arrange a demonstration at your clinic or at one of the partner medical centres we work with, where training days are also held. Fill in the form below.

CONTACT US

REQUEST INFORMATION

    See Privacy Policy