Lutronic eCO2 Plus fractional CO2 laser for resurfacing, scars and skin rejuvenation

From deep ablative resurfacing to light, low-downtime treatments, with a single CO2 laser.

Lutronic eCO2 Plus 10,600 nm fractional CO2 laser
Cynosure Lutronic logo

WHY CHOOSE IT

LUTRONIC ECO2 PLUS BENEFITS

1

From light to deep treatments

2 to 160 mJ of energy and EcoTone mode: from intense ablative resurfacing to light, low-downtime treatments.

2

Controlled Chaos Technology

Each microbeam lands as far as possible from the previous one: less bulk heating of the tissue and shorter recovery.

3

No consumables

120, 300 and 500 µm tips included as standard and no per-treatment consumables.

Skin rejuvenation treatment with the Lutronic eCO2 fractional CO2 laser

eCO2 Plus is manufactured by Cynosure Lutronic. Bioskin Italia distributes it in Italy and supports every installation with clinical training, technical service and marketing support.

THE PRODUCT

What is Lutronic eCO2 Plus

Lutronic eCO2 Plus is a 10,600 nm fractional CO2 laser with 30 W of power, designed for ablative skin resurfacing. The beam is split into microbeams that vaporize microscopic columns of tissue and trigger collagen remodelling, while leaving the skin between the columns intact. It is designed for dermatologists, aesthetic physicians and plastic surgeons who want to treat scars, wrinkles, texture and skin lesions with one device.

Fractional CO2 laser treatment for acne scars

THE TECHNOLOGY

How the fractional CO2 laser works

10,600 nm light is absorbed by the water in the tissue. Each microbeam vaporizes a column of tissue surrounded by a coagulation zone: the skin heals from the surrounding healthy tissue, producing new collagen and renewing the epidermis.

120, 300 and 500 µm tips

The 120 µm tip creates narrow, deep columns, up to 2.4 mm at 160 mJ, suited to scars and deep wrinkles. The 300 µm tip creates wider, shallower columns for texture and dyschromia. The 500 µm tip, also included as standard, completes the set.

Controlled Chaos Technology (CCT)

Microbeams are delivered in random order rather than in sequence, each one as far as possible from the last. The tissue has time to cool between pulses, reducing the risk of bulk heating and post-inflammatory hyperpigmentation (PIH).

EcoTone: low-downtime resurfacing

At low energy and density eCO2 Plus also performs light rejuvenation treatments with short recovery. The same device serves both patients who want a marked result and those who cannot take time off.

Adjustable density and scan area

Density from 25 to 400 spots/cm², scan area up to 18 × 18 mm, static or dynamic scanning and a repetition rate up to 200 Hz: every parameter adapts to the area and skin type.

INDICATIONS

What eCO2 Plus treats

Resurfacing and rejuvenation

  • Wrinkles and fine lines
  • Furrows
  • Uneven skin texture
  • Dyschromia
  • Actinic and solar elastosis

For non-ablative resurfacing and pigmentation: Lutronic LaseMD Ultra.

Scars

  • Acne scars
  • Surgical scars
  • Burn scars
  • Keloids

Skin lesions and dermatologic surgery

  • Pigmented lesions and lentigines
  • Actinic keratosis
  • Xanthelasma palpebrarum
  • Syringoma
  • Rhinophyma
  • Ablation, incision and excision of soft tissue

See all the skin resurfacing and rejuvenation devices distributed by Bioskin Italia.

SPECIFICATIONS

Technical data

Laser type Fractional CO2, 10,600 nm
Power 30 W
Delivery system Articulated arm with handpiece
Tips (microbeam) 120, 300 and 500 µm, included as standard
Pulse energy 2 to 160 mJ
Repetition rate 10–200 Hz
Density 25–400 spots/cm²
Scan area Up to 18 × 18 mm; static and dynamic scanning
Maximum depth Up to 2.4 mm (120 µm tip at 160 mJ)
Technologies Controlled Chaos Technology, EcoTone mode
Dimensions 36.1 × 45.0 × 186.9 cm (W × D × H)
Weight 48 kg
Power supply 100–240 V AC, 50/60 Hz; 800 VA

RESULTS, NOT WORDS

ECO2 PLUS: BEFORE AND AFTER

Before treatment with the Lutronic eCO2 fractional CO2 laserAfter treatment with the Lutronic eCO2 fractional CO2 laser
Scar before treatment with the Lutronic eCO2 fractional CO2 laserScar after treatment with the Lutronic eCO2 fractional CO2 laser

eCO2 Plus with Bioskin Italia

Bioskin Italia has been distributing aesthetic medicine devices since 1997. With eCO2 Plus we provide installation and clinical training at your practice or through training days at the partner medical centres we work with, after-sales technical service and maintenance contracts, and marketing support to launch the treatment.

eCO2 Plus is also available through leasing or operating rental.

FAQ

eCO2 Plus FAQ

What is the difference between ablative and non-ablative fractional lasers?

An ablative CO2 laser vaporizes columns of tissue and produces the strongest remodelling: it is the choice for scars, deep wrinkles and texture. Non-ablative lasers leave the surface intact, with more gradual results and shorter recovery. In EcoTone mode eCO2 Plus also performs light treatments.

Which tip is used for acne scars and wrinkles?

The 120 µm tip reaches the greatest depth and is suited to acne scars and deep wrinkles. The 300 µm tip works more superficially over a wider area, for texture and dyschromia.

What is the recovery time?

It depends on energy and density. After a deep ablative treatment, redness and small crusts appear for a few days; with EcoTone and light settings recovery is shorter. CCT limits bulk heating of the tissue and helps keep recovery time down.

Are consumables required?

No: eCO2 Plus uses no consumables, and the 120, 300 and 500 µm tips are included as standard.

Can I see eCO2 Plus in action before buying?

Yes: we can arrange a demonstration at your practice or at one of the partner medical centres we work with, where training days are also held. Fill in the form below.

CONTACT US

REQUEST INFORMATION

    See Privacy Policy