CYNOSURE LUTRONIC
Lutronic Clarity II 755 nm alexandrite and 1064 nm Nd:YAG laser for hair removal and vascular lesions
Two wavelengths in one laser: hair removal on all skin types, vascular and pigmented lesions.
WHY CHOOSE IT
LUTRONIC CLARITY II BENEFITS
1
Two wavelengths
755 nm alexandrite and 1064 nm Nd:YAG through the same fibre: one laser for light and dark skin types.
2
IntelliTrak
Large-area treatments more than 2× faster, with real-time skin temperature monitoring.
3
1 ms pulse for fine hair
An exclusive 1 ms pulse designed for fine hair, the hardest to treat with laser hair removal.
Clarity II is manufactured by Cynosure Lutronic. Bioskin Italia distributes it in Italy and supports every installation with clinical training, technical service and marketing support.
THE PRODUCT
What is Lutronic Clarity II
Lutronic Clarity II is a dual-wavelength laser that combines 755 nm alexandrite and 1064 nm Nd:YAG in a single fibre. It is designed for laser hair removal (permanent hair reduction) on all skin types and for treating vascular and pigmented lesions. With fluence up to 600 J/cm² and spot sizes up to 25 mm, it is aimed at dermatologists, aesthetic physicians and medical centres that want one laser for hair removal and dermatology.
THE TECHNOLOGY
How Clarity II works
Clarity II relies on selective photothermolysis: the laser light is absorbed by a precise target, the melanin in hair or pigmented spots or the haemoglobin in vessels, which heats up and is destroyed while the surrounding tissue is spared. The wavelength determines which target is hit and at what depth.
755 nm alexandrite
The wavelength most strongly absorbed by melanin: highly effective on dark hair in light and intermediate skin types, and on benign pigmented lesions such as lentigines and sun spots.
1064 nm Nd:YAG
It penetrates deeper and is less absorbed by epidermal melanin: the choice for hair removal on dark skin types and for deeper vessels such as leg veins.
IntelliTrak and temperature monitoring
IntelliTrak technology makes treating large areas such as legs and back more than 2× faster. Real-time skin temperature feedback helps the operator work safely throughout the session.
Spot sizes, pulses and cooling
Spot sizes from 2 to 25 mm, pulses from 0.1 to 300 ms (including the 1 ms pulse for fine hair) and cold-air (Zimmer) or cryogen (ICD) skin cooling to protect the epidermis and improve comfort.
INDICATIONS
What Clarity II treats
Laser hair removal
- Permanent hair reduction
- All skin types, including dark skin
- Fine hair (1 ms pulse)
- Large areas such as legs and back
See also our diode laser hair removal machines.
Vascular lesions
- Port-wine stains
- Haemangiomas
- Telangiectasia and rosacea
- Venous lakes
- Leg veins and spider veins
For a dedicated vascular laser: Lutronic DermaV.
Pigmented lesions and other indications
- Lentigines and sun spots
- Café-au-lait macules
- Chloasma
- Seborrheic keratosis
- Warts and skin tags
- Wrinkles and skin revitalization
See all the technologies for treating cutaneous vascular lesions distributed by Bioskin Italia.
SPECIFICATIONS
Technical data
| Wavelengths | 755 nm (alexandrite) and 1064 nm (Nd:YAG) |
| Delivery system | Single lens-coupled optical fibre |
| Maximum energy | 60 J (755 nm) / 100 J (1064 nm) |
| Maximum fluence | 600 J/cm² |
| Pulse duration | 0.1–300 ms, including a 1 ms pulse for fine hair |
| Repetition rate | 0.5–10 Hz |
| Spot sizes | 2, 3–5, 8–10–12, 15–18–22, 16–20–25 mm |
| Technologies | IntelliTrak, real-time skin temperature feedback |
| Cooling | Cold air (Zimmer) or cryogen (ICD) |
| Controls | Finger switch and foot switch; standby to ready in 12 s |
| Dimensions | 56.4 × 95.3 × 99.8 cm (W × D × H) |
| Weight | 110 kg |
| Power supply | 220–230 V, 6.0 kVA, 30 A |
RESULTS, NOT WORDS
CLARITY II: BEFORE AND AFTER


Clarity II with Bioskin Italia
Bioskin Italia has been distributing aesthetic medicine devices since 1997. With Clarity II we provide installation and clinical training at your practice or through training days at the partner medical centres we work with, after-sales technical service and maintenance contracts, and marketing support to launch the treatment.
Clarity II is also available through leasing or operating rental.
FAQ
Clarity II FAQ
Which skin types can Clarity II treat?
All of them. The 755 nm alexandrite suits light and intermediate skin types; the 1064 nm Nd:YAG, less absorbed by epidermal melanin, allows safe treatment of dark and tanned skin too.
What is the difference between an alexandrite laser and a diode laser?
755 nm light is absorbed by melanin more strongly than diode light (around 800–810 nm), which makes alexandrite particularly effective on light and fine hair. Clarity II pairs alexandrite with 1064 nm Nd:YAG, extending treatment to dark skin.
How many sessions does laser hair removal take?
It depends on the area, skin type and hair colour and thickness. The laser acts on hair in the growth phase, so treatment is delivered as a course of several sessions spaced over time, set by the physician.
Does Clarity II also treat spider veins and leg veins?
Yes. The 1064 nm Nd:YAG is indicated for leg veins and deeper vessels; the laser also treats telangiectasia, rosacea, port-wine stains and haemangiomas. For a practice focused mainly on vascular work, consider Lutronic DermaV as well.
Can I see Clarity II in action before buying?
Yes: we can arrange a demonstration at your practice or at one of the partner medical centres we work with, where training days are also held. Fill in the form below.